REFERENCES
Extract about our services | |||||||||||||||||||||
|
Single- and double family houses
Renovation of a listed “Art Nouveau” town house in Berlin-LichterfeldeMeasuresGas fired condensing technology Basic dataYear of construction: Surface Area/An: 375 m² Primary energy requirement Energy Savings: 61 % CO2-reduction: 28.515 kg/a Single family house with annexe to existing building in Berlin-DahlemMeasuresAssembly of a wood-pellets- Basic dataYear of construction: Surface Area/An: 423 m² Primary energy requirement Energy Savings: 44 % CO2-reduction: 41.167 kg/a Detached-row-house in Berlin-SpandauMeasuresGas fired condensing technology Insulation of the facade with ecological insulating materials Insulate basement ceiling Basic dataYear of construction: Surface Area/An: 139,8 m² Primary energy requirement Energy Savings: 46 % CO2-reduction: 42.342 kg/a Villa / detached house in Berlin-HessenwinkelMeasuresCentral heating with gas fired condensing technology Solar thermal technology Ventilation and heat recovery Insulation of the facade with ecological insulating materials Insulate basement ceiling Basic dataYear of construction: Surface Area/An: 237 m² Primary energy requirement Energy Savings: 84 % CO2-reduction: 77.091 kg/a Single family house in Berlin-WilhelmshagenMeasuresAssembly of a wood-pellets- Solar thermal technology Insulation of the facade with ecological insulating materials Insulate basement ceiling Basic dataYear of construction: Surface Area/An: 237 m² Primary energy requirement Energy Savings: 77 % CO2-reduction: 6.163 kg/a Double family house in Berlin-HessenwinkelMeasuresCentral heating with gas fired condensing technology Heat-protective glazing Insulation of the facade and of the cellar ceiling with ecological insulating materials Insulation of the top floor ceiling Insulation of the garage door system Basic dataYear of construction: Surface Area/An: 445 m² Primary energy requirement Energy Savings: 53 % CO2-reduction: 10.100 kg/a Single family house in Berlin-WannseeMeasuresCentral heating with gas fired condensing technology Solar thermal technology Ventilation and heat recovery Insulation of the facade with ecological insulating materials Insulate basement ceiling Basic dataYear of construction: Surface Area/An: 294 m² Primary energy requirement Energy Savings: 49,8 % CO2-reduction: 44.524 kg/a Villa in Berlin-LichterfeldeMeasuresGas fired condensing technology Insulate basement ceiling Insulation of the roof 30 cm Triple heat-protective glazing Basic dataYear of construction: Surface Area/An: 375 m² Primary energy requirement Energy Savings: 59 % CO2-reduction: 27.967 kg/a |
|||||||||||||||||||||
|
||||||||||||||||||||||
|